Hikvision DS-UPS2000 2000VA/1200W Uninterruptible Power Supply
The Hikvision DS-UPS2000 is a 2000 VA / 1200 W line-interactive uninterruptible power supply that keeps your equipment running through blackouts, brownouts and surges. Built-in automatic voltage regulation (AVR) smooths out unstable mains, four AU outlets feed your gear, and an LCD plus USB port let you monitor and manage it. It is an ideal back-up for CCTV recorders, networking and point-of-sale equipment.
Key points
- 2000 VA / 1200 W line-interactive UPS with AVR
- About 70 minutes' runtime at a 100 W load
- Four AU Type I outlets; fast transfer time under 10 ms
- LCD display plus USB port for monitoring and safe shutdown
- Wide 140-290 VAC input; surge, overload and short-circuit protection
- Two replaceable 12 V 9 Ah batteries; recharge to 90% in 6-8 hours
inc GST + 3 Year Warranty & Support
Free shipping over AUD300
Build your setup Build a complete CCTV system
A camera needs an NVR, a hard drive, and cabling to work. Add everything below, or pick a ready-made kit.
3-Year Warranty
Warranty on all cameras
Free Shipping
On orders over $300
30-Day Returns
Easy returns for unopened items
Fast Delivery
5-10 Day Delivery Australia-wide
§ 01Overview
What the DS-UPS2000 is
The Hikvision DS-UPS2000 is a line-interactive uninterruptible power supply rated at 2000 VA / 1200 W, designed to keep important equipment online when the mains power dips or drops out.
When the power fails it switches to its internal batteries in under 10 milliseconds, fast enough that connected devices keep running without rebooting.
Built-in automatic voltage regulation (AVR) corrects an unstable supply, accepting a wide 140 to 290 VAC input and delivering a steady 210 to 235 VAC output, which protects sensitive electronics from brownouts and over-voltage without constantly draining the batteries.
Full protection covers surge, overload, discharge and short circuit, and audible alarms signal charging, low battery, overload and fault conditions.
Four AU Type I outlets feed your equipment, an LCD shows input and output voltage, battery capacity and load level, and a USB port allows monitoring and safe automatic shutdown from a connected computer.
Power comes from two 12 V 9 Ah sealed lead-acid batteries, which recharge to 90% in 6 to 8 hours and are replaceable when they reach end of life.
Runtime depends on load - roughly 70 minutes at 100 W, 17 minutes at 300 W and 5 minutes at 600 W - so it is well matched to CCTV recorders, network switches, routers, VoIP and point-of-sale gear rather than heavy loads.
It measures 345 x 122 x 192 mm, weighs about 11 kg, and is genuine Australian stock with local warranty and support.
§ 02Engineering
DS-UPS2000 specifications
- Fast transfer to battery in under 10 ms on power loss
- Wide 140-290 VAC input; regulated 210-235 VAC output
- About 70 min runtime at 100 W (17 min at 300 W, 5 min at 600 W)
- Four AU Type I outlets for your equipment
- LCD shows input/output voltage, battery capacity and load level
- USB port for monitoring and safe automatic shutdown
- Surge, overload, discharge and short-circuit protection with audible alarms
- Two replaceable 12 V 9 Ah batteries; recharge to 90% in 6-8 hours
§ 03Full datasheet
Detailed specifications
Camera & Image
| Feature | Detail |
|---|
Lens & Distance
| Feature | Detail |
|---|
Night Vision
| Feature | Detail |
|---|
Video
| Feature | Detail |
|---|
Audio
| Feature | Detail |
|---|---|
| Alarm | Charging Mode (DC mode): Sounding every 8 seconds; Low Battery: Sounding every second; Overloading Mode: Sounding every 0.5 seconds; Fault: Continuously sounding |
AI & Deep Learning
| Feature | Detail |
|---|
Network & Storage
| Feature | Detail |
|---|
Event & Alarm
| Feature | Detail |
|---|---|
| Full Protection | Surge protection, Overload protection, Discharge protection, Short circuit protection |
Interface
| Feature | Detail |
|---|---|
| Communicate Ports | USB |
| Outlet Type | AU TYPE I |
| Outlet Number | 4 |
| Display | LCD Screen; Input Voltage, Output Voltage, Battery capacity, load level |
General & Environment
| Feature | Detail |
|---|---|
| UPS Capacity | 2000 VA / 1200 W |
| Input Voltage Range | 140 VAC to 290 VAC |
| Input Frequency | 50/60 Hz self-adaptive |
| Plug Type | AU TYPE I |
| Output Voltage Range | 210 VAC to 235 VAC |
| Output Frequency | 50/60 Hz ± 0.5 Hz self-adaptive |
| Transfer Time | ≤ 10 ms |
| Waveform | PWM |
| Battery Type | 12 V/9 Ah *2 pcs, lead-acid battery |
| Recharge Time | 6-8 hours recover to 90% capacity |
| Typical Backup Time | Run time at 100w: 70 min; Run time at 300w: 17 min; Run time at 600w: 5 min |
| Operating Temperature | 0 °C to 40 °C (32 °F to 104 °F) |
| Operating Humidity | 30% to 90% (non-condensing) |
| Dimension | 345 mm × 122 mm × 192 mm (13.58" × 4.80" × 7.56") |
| Weight | Approx. 11 kg (24.3 lb) |
§ 04Why choose this
Built for the way you actually use the DS-UPS2000
Cleans up unstable mains
Built-in AVR holds a steady 210-235 V output across a wide 140-290 V input, protecting equipment from brownouts and over-voltage, not just blackouts.
See and manage it
An LCD shows voltage, battery and load at a glance, while the USB port enables monitoring and automatic safe shutdown from a connected computer.
Serviceable and well protected
Replaceable 12 V 9 Ah batteries and full surge, overload, discharge and short-circuit protection make it a practical, long-term back-up.
§ 05Where it fits
Right at home in these scenarios
CCTV recorders
Keep an NVR or DVR and the PoE switch feeding the cameras running through blackouts so you do not lose footage or have the recorder reboot.
Network and internet gear
Back up a modem, router and switch so the internet, Wi-Fi and remote access stay up during short outages.
Point-of-sale and small office
Protect POS terminals, a small server or NAS and phones so a business keeps trading and shuts down safely if the outage is long.
Voltage protection in rural areas
Use the AVR to steady an unstable or fluctuating rural supply that would otherwise stress sensitive electronics.
§ 06Setup
Installation & setup
What's in the box
One DS-UPS2000 UPS with its internal batteries and a USB cable. Monitoring software is downloaded from the manufacturer; the equipment you protect is not included.
Installation requirements
Place the UPS on a firm, ventilated surface, plug it into a properly earthed wall socket and let it charge before relying on it. Connect your equipment to the four AU outlets, keeping the total within 1200 W, and connect the USB cable to a computer if you want monitoring and automatic shutdown. Check the LCD shows normal input/output voltage and a healthy battery, and test by briefly removing mains power. Replace the lead-acid batteries when capacity drops at end of life.
§ 07Questions
Frequently asked about the DS-UPS2000
Q.01
What can the DS-UPS2000 run and for how long?
Q.02
Is it a true online (double-conversion) UPS?
Q.03
Can I replace the batteries?
Q.04
How many devices can I plug in?
Q.05
Does it protect against surges and unstable power?
Q.06
Can it shut my system down safely and show its status?
Q.07
Will it keep my CCTV cameras recording during a blackout?
§ 09Bundles
Recommended packages
Back up your recorder
Keep a Hikvision DS-7608NI-I2/8P NVR or DS-7608NI-M2/8P NVR, or a HiLook NVR-216MH-C-16P NVR, running through outages.
Protect a whole camera kit
Pair it with a full system such as the 8MP 8-camera AcuSense kit so the recorder and PoE switch stay powered.