Vendor: Hikvision

Hikvision DS-PM1-O1H-WB Wall Switch

SKU: DS-PM1-O1H-WB
Description

The Hikvision DS-PM1-O1H-WB is a wireless wall switch for AX PRO alarm systems, with a high-power relay that switches mains circuits directly. Linked to your alarm by 433MHz two-way wireless, it can turn lighting or appliances on and off on an alarm, a schedule or a manual command - no control cable back to the hub.

At a glance
- Single relay output, NO/NC, 100-240V AC up to 13A - switches mains loads directly
- 433MHz two-way wireless (2GFSK) to the AX PRO hub, up to 800m, AES-128 encrypted
- Scenario control: by alarm, by operation, by fault, by schedule or manual
- Mains powered (100-240V AC, 50/60Hz); wall mount or inside a standard 86 box
- Three status LEDs (register/signal, power, relay); licensed electrician required for mains wiring

Regular price $45.60 AUD Sale price $45.60 AUD Regular price $68.00 AUD
Sale 32.94% $22.40 AUD (32.94%)
Business or bulk buyer? Apply for trade pricing →
Found a lower price? We’ll match it →

inc GST + 3 Year Warranty & Support
Free shipping over AUD300

In stock
3-Year WarrantyOn all cameras
Free ShippingOn orders over $300
30-Day ReturnsUnopened items
Fast Delivery1–5 days Australia-wide
Build your setup Build a complete CCTV system

A camera needs an NVR, a hard drive, and cabling to work. Add everything below, or pick a ready-made kit.

Add accessories Optional. Junction box → hides & weatherproofs cable joins (best for outdoors). Brackets → only if mounting on a corner or under eaves. Cable → one per camera; skip if you already have your own.
0
0
0
0
0
Bundle total: $45.60

§ 01Overview

What the DS-PM1-O1H-WB is

The Hikvision DS-PM1-O1H-WB is a wireless wall switch and relay output module for AX PRO alarm systems. It lets the alarm control real-world devices: its high-power relay switches a mains circuit directly, so lighting, a pump, a roller door controller or another appliance can be turned on or off as part of the system's response - all linked over wireless rather than a wired output run.

The single relay provides normally-open and normally-closed contacts rated for 100-240V AC at up to 13A, controlling mains loads without an external contactor. Flexible scenario settings let it react automatically by alarm, by operation, by fault or on a schedule, as well as on a manual command, so it can drive deterrent lighting on an intrusion or switch equipment by time of day.

It communicates on 433MHz two-way wireless (2GFSK) with AES-128 security, rated up to 800m in open space, and is powered from the mains (100-240V AC, 50/60Hz). Three LEDs show registration and signal, power, and relay status, and it mounts on the wall or inside a standard 86 box. Because it switches mains voltage, installation and wiring must be carried out by a licensed electrician in line with local regulations, and the connected load must stay within the 13A rating. This is the high-power (O1H) model; a low-voltage output module is available for dry-contact switching.

§ 02Engineering

DS-PM1-O1H-WB specifications

- Single relay output with NO/NC contacts rated 100-240V AC at up to 13A, switching mains loads directly without an external contactor.

- 433MHz two-way wireless (2GFSK) to the AX PRO hub with AES-128 security, rated up to 800m in open space.

- Scenario control by alarm, by operation, by fault, by schedule or manual, so output can follow the alarm or the clock.

- Mains powered (100-240V AC, 50/60Hz); wall mount or fits inside a standard 86 box for a tidy install.

- Three status LEDs show registration and signal, power, and relay state for easy commissioning.

- Switches mains voltage, so installation must be done by a licensed electrician and the load kept within the 13A rating.

§ 03Full datasheet

Detailed specifications

Network & Storage

Network & Storage — Hikvision DS-PM1-O1H-WB Wall Switch
FeatureDetail
RF frequency 433MHz
RF method Two way communication
RF modulation 2GFSK
RF distance 800m
Wireless security Supported

§ 04Why choose this

Built for the way you actually use the DS-PM1-O1H-WB

Switch mains directly

A 13A relay handles 100-240V AC loads without an external contactor, so it can drive lighting or appliances on its own.

Automation from the alarm

Scenario control by alarm, schedule, fault or manual lets the system turn devices on and off as part of its response.

No control cabling

433MHz two-way wireless to 800m means the output can sit where the load is, not where the hub is.

Tidy install

It mounts on the wall or inside a standard 86 box, with clear status LEDs for commissioning.

§ 05Where it fits

Right at home in these scenarios

Deterrent lighting

Switch external or internal lighting on automatically when the alarm is triggered.

Scheduled switching

Turn signage, lighting or equipment on and off by time of day through the system.

Garages and utility areas

Control a compatible mains device in a garage, plant room or service area.

Alarm-linked devices

Drive a connected mains load as part of an AX PRO alarm response.

§ 06Setup

Installation & setup

01

Plan the circuit

Confirm the load is within the 13A rating and plan the mains wiring; this work must be done by a licensed electrician.

02

Mount and wire

Fit it on the wall or inside a standard 86 box and wire the mains supply and the NO/NC output to the load.

03

Pair to the hub

Use the learning button to enrol it to the AX PRO hub and check the registration and signal LED.

04

Set scenarios and test

Configure the trigger scenarios in the app, then test switching by alarm, schedule and manual command.

§ 07Questions

Frequently asked about the DS-PM1-O1H-WB

Q.01

What does the DS-PM1-O1H-WB do?

It is a wireless relay module that lets your AX PRO alarm switch a mains circuit. Its relay can turn lighting or an appliance on and off on an alarm, a schedule or a manual command, controlled over wireless.
Q.02

How much load can the relay switch?

The single relay is rated for 100-240V AC at up to 13A on normally-open or normally-closed contacts. Keep the connected load within that rating.
Q.03

Does it need an electrician to install?

Yes. Because it switches mains voltage, wiring must be carried out by a licensed electrician in line with local electrical regulations.
Q.04

How is it different from a low-voltage output module?

This O1H model switches mains directly at up to 13A. A low-voltage output module provides a dry contact for low-voltage signalling and needs a separate contactor to switch mains.
Q.05

How does it connect to the alarm?

Over 433MHz two-way wireless (2GFSK) with AES-128 security, rated up to 800m in open space, so there is no control cable back to the hub.
Q.06

What can trigger the output?

Scenario settings let it react by alarm, by operation, by fault or on a schedule, as well as on a manual command from the app.
Q.07

How is it powered?

From the mains, 100-240V AC at 50/60Hz. It is not battery powered, so it needs a permanent supply at the mounting point.
Q.08

Where can I mount it?

On the wall or inside a standard 86 mounting box, in a suitable protected position wired by a licensed electrician.

§ 09Bundles

Recommended packages

04

Control at the door

Add a DS-PK1-LT-WB keypad to arm, disarm and operate the system.